Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Radiol. bras ; 56(3): 137-144, May-June 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1449034

ABSTRACT

Abstract Objective: To develop an automated co-registration system and test its performance, with and without a fiducial marker, on single-photon emission computed tomography (SPECT) images. Materials and Methods: Three SPECT/CT scans were acquired for each rotation of a Jaszczak phantom (to 0°, 5°, and 10° in relation to the bed axis), with and without a fiducial marker. Two rigid co-registration software packages-SPM12 and NMDose-coreg-were employed, and the percent root mean square error (%RMSE) was calculated in order to assess the quality of the co-registrations. Uniformity, contrast, and resolution were measured before and after co-registration. The NMDose-coreg software was employed to calculate the renal doses in 12 patients treated with 177Lu-DOTATATE, and we compared those with the values obtained with the Organ Level INternal Dose Assessment for EXponential Modeling (OLINDA/EXM) software. Results: The use of a fiducial marker had no significant effect on the quality of co-registration on SPECT images, as measured by %RMSE (p = 0.40). After co-registration, uniformity, contrast, and resolution did not differ between the images acquired with fiducial markers and those acquired without. Preliminary clinical application showed mean total processing times of 9 ± 3 min/patient for NMDose-coreg and 64 ± 10 min/patient for OLINDA/EXM, with a strong correlation between the two, despite the lower renal doses obtained with NMDose-coreg. Conclusion: The use of NMDose-coreg allows fast co-registration of SPECT images, with no loss of uniformity, contrast, or resolution. The use of a fiducial marker does not appear to increase the accuracy of co-registration on phantoms.


Resumo Objetivo: Desenvolver corregistro automático e testar seu desempenho com ou sem marcador fiducial em imagens de tomografia computadorizada de emissão de fóton único (SPECT). Materiais e Métodos: Três SPECT/CTs foram adquiridas para cada rotação de um simulador de Jaszczak em relação ao eixo da maca (0°, 5° e 10°), com e sem fiducial. Dois métodos de corregistro inelástico foram aplicados - SPM12 e NMDose-coreg -, e a porcentagem do erro quadrático médio (%RMSE) foi usada para analisar a qualidade do corregistro. Uniformidade, contraste e resolução foram medidos antes e após o corregistro. NMDose com corregistro automático foi usado para calcular a dose renal de 12 pacientes tratados com 177Lu-DOTATATE e comparado com OLINDA/EXM. Resultados: A marcação fiducial não modificou a qualidade do corregistro das imagens SPECT, medida pela %RMSE (p = 0,40). Não houve impacto na uniformidade, contraste e resolução após o corregistro de imagens adquiridas com ou sem fiduciais. Aplicação clínica preliminar mostrou tempo total de processamento de 9 ± 3 min/paciente para NMDose e 64 ± 10 min/paciente para OLINDA/EXM, com alta correlação entre ambos, apesar de menor dose renal em NMDose. Conclusão: NMDose-coreg permite o corregistro rápido de imagens SPECT, sem perda de uniformidade, contraste ou resolução. O uso da marcação fiducial não aumentou a precisão do corregistro em fantomas.

2.
Dement. neuropsychol ; 17: e20220095, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1528505

ABSTRACT

ABSTRACT Primary progressive aphasia is a clinical syndrome caused by neurodegeneration of areas and neural networks involved in language, usually in the left hemisphere. The term "crossed aphasia" denotes an acquired language dysfunction caused by a lesion in the ipsilateral hemisphere to the dominant hand. Objective: To describe a case of crossed aphasia in a 60-year-old left-handed patient with a non-fluent variant of primary progressive aphasia diagnosis (age of onset=52), evidenced by a left asymmetry on brain SPECT scan. Methods: Clinical and family history, the Edinburgh Handedness Inventory, Measurement of Functional Activities in Older Adults in the Community, the "Mini-Mental State Examination", the Trail Making Test, the Tower of London, and the Neuropsychological assessment for dementia, and neuroimaging studies were carried out. Results: Neuropsychological assessment showed severe cognitive impairment, especially regarding language. The magnetic resonance imaging showed important signs of cortico-subcortical atrophy, with predominance in the frontal and temporal lobes. The single-photon emission computed tomography scan showed moderate to severe hypoperfusion in the left cerebral hemisphere, including the hippocampus. Conclusion: We described a clinical case of crossed aphasia in a left-handed woman with a non-fluent variant of primary progressive aphasia with asymmetry on brain SPECT, mainly on the left, followed up for seven years.


RESUMO A afasia progressiva primária é uma síndrome clínica causada por uma neurodegeneração de áreas e redes neurais envolvidas na linguagem, geralmente no hemisfério esquerdo. O termo "afasia cruzada" denota uma disfunção adquirida de linguagem causada por uma lesão no hemisfério ipsilateral da mão dominante. Objetivo: Relatamos um caso de afasia cruzada em uma paciente de 60 anos, canhota, com um quadro clínico de afasia progressiva primária variante não fluente (idade de início=52), evidenciada por assimetria no SPECT cerebral à esquerda. Métodos: Foram realizados para o diagnóstico do caso: história clínica e familiar, o Inventário de Dominância de Edinburgh, a Escala de Atividades Funcionais de Pfeffer, o Miniexame do Estado Mental, o Teste das Trilhas, o Teste da Torre de Londres, a Avaliação Neuropsicológica Adequada às Demências e exames de neuroimagem. Resultados: A avaliação neuropsicológica mostrou comprometimento cognitivo severo, principalmente sobre a linguagem; a ressonância magnética do crânio mostrou sinais de involução córtico-subcortical, com predominância nos lobos frontal e temporal e a cintilografia cerebral por emissão de fóton único mostrou hipoperfusão moderada a severa no hemisfério cerebral esquerdo, incluindo o hipocampo. Conclusão: Registramos um caso clínico de afasia cruzada em uma paciente canhota com afasia progressiva primária variante não fluente com assimetria no SPECT cerebral, principalmente à esquerda, seguida há sete anos.

3.
Radiol. bras ; 54(4): 232-237, July-Aug. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1287747

ABSTRACT

Abstract Objective: To determine whether technetium-99m-labeled tropane derivative single-photon emission computed tomography (99mTc-TRODAT-1 SPECT) provides results comparable to those of the less widely available, less accessible tool fluorine-18-labeled fluorodopa positron-emission tomography (18F-FDOPA PET) in the setting of a movement disorders clinic. Materials and Methods: In this prospective pilot study, eight subjects with a clinical diagnosis of Parkinson's disease were randomly selected from among patients under treatment at a movement disorders clinic and submitted to 99mTc-TRODAT-1 SPECT and 18F-FDOPA PET. The results were read by two experienced observers, and a semiquantitative analysis was performed. Results: The visual and semiquantitative analyses were concordant for all studies, showing that radiotracer uptake in the contralateral striatum on the most affected side was lower when 99mTc-TRODAT-1 SPECT was employed. The semiquantitative analysis demonstrated a significant correlation between 18F-FDOPA PET and 99mTc-TRODAT-1 SPECT (r = 0.73; p < 0.01). Conclusion: It appears that 99mTc-TRODAT-1 SPECT is a valid option for the study of dopaminergic function in a clinical setting.


Resumo Objetivo: Determinar se a 99mTc-TRODAT-1 SPECT fornece resultados comparáveis aos da 18F-FDOPA PET, ferramenta menos acessível e menos amplamente disponível, no contexto de uma clínica de distúrbios do movimento. Materiais e Métodos: Neste estudo prospectivo, oito indivíduos com diagnóstico clínico de doença de Parkinson foram selecionados aleatoriamente entre pacientes em tratamento em uma clínica de distúrbios do movimento e submetidos a 99mTc-TRODAT-1 SPECT e 18F-FDOPA PET. Os resultados foram lidos por dois observadores experientes e uma análise semiquantitativa foi realizada. Resultados: As análises visual e semiquantitativa foram concordantes para todos os estudos, mostrando que a captação do radiotraçador no estriado contralateral do lado mais afetado foi menor quando a 99mTc-TRODAT-1 SPECT foi empregada. A análise semiquantitativa demonstrou uma correlação significativa entre 18F-FDOPA PET e 99mTc-TRODAT-1 SPECT (r = 0,73; p < 0,01). Conclusão: A 99mTc-TRODAT-1 SPECT parece ser uma opção válida para o estudo da função dopaminérgica em um ambiente clínico.

6.
Arq. bras. cardiol ; 113(6): 1092-1101, Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1055064

ABSTRACT

Abstract Background: Functional assessment to rule out myocardial ischemia using coronary computed tomography angiography (CCTA) is extremely important and data on the Brazilian population are still limited. Objective: To assess the diagnostic performance of myocardial perfusion by CCTA in the detection of severe obstructive coronary artery disease (CAD) compared with single-photon emission computerized tomography (SPECT). To analyze the importance of anatomical knowledge to understand the presence of myocardial perfusion defects on SPECT imaging that is not identified on computed tomography (CT) scan. Method: A total of 35 patients were evaluated by a simultaneous pharmacologic stress protocol. Fisher's exact test was used to compare proportions. The patients were grouped according to the presence or absence of significant CAD. The area under the ROC curve was used to identify the diagnostic performance of CCTA and SPECT in perfusion assessment. P < 0.05 values were considered statistically significant. Results: For detection of obstructive CAD, CT myocardial perfusion analysis yielded an area under the ROC curve of 0.84 [a 95% confidence interval (CI95%): 0.67-0.94, p < 0.001]. SPECT myocardial perfusion imaging, on the other hand, showed an AUC of 0.58 (95% CI 0.40 - 0.74, p < 0.001). In this study, false-positive results with SPECT are described. Conclusion: Myocardial perfusion analysis by CTA displays satisfactory results compared to SPECT in the detection of obstructive CAD. CCTA can rule out false-positive results of SPECT.


Resumo Fundamento: A avaliação funcional para descartar a isquemia miocárdica utilizando a angiotomografia computadorizada (angio-TC) de coronárias é de extrema importância e dados na população brasileira ainda são escassos. Objetivo: Avaliar o desempenho diagnóstico da perfusão miocárdica pela angio-TC de coronárias na detecção de doença arterial coronariana (DAC) obstrutiva significativa em comparação com a tomografia computadorizada por emissão de fóton único (SPECT; do inglês, single photon emission computerized tomography). Analisar a importância do conhecimento anatômico para entender a presença de defeito de perfusão miocárdica pela SPECT que não é identificado pela tomografia computadorizada (TC). Método: Trinta e cinco pacientes foram avaliados por um protocolo de estresse farmacológico simultâneo. O teste exato de Fisher foi utilizado para comparação entre as proporções. Os pacientes foram agrupados de acordo com a presença ou não de DAC significativa. A área sob a curva foi utilizada para identificar o desempenho diagnóstico da avaliação da perfusão pela angio-TC de coronárias e pela SPECT. Os valores de p < 0,05 foram considerados estatisticamente significativos. Resultados: Para detecção de DAC obstrutiva a avaliação da perfusão miocárdica pela TC teve uma área sob a curva de 0,84 [intervalo de confiança de 95% (IC95%): 0,67 a 0,94, p < 0,001]. Já o estudo da perfusão miocárdica pela SPECT foi de 0,58 (IC95%: 0,40 a 0,74, p < 0,001). Neste estudo, foram descritos falso-positivos pela SPECT. Conclusão: A avaliação da perfusão miocárdica pela angio-TC apresenta resultados satisfatórios em comparação com os da SPECT na detecção de DAC obstrutiva. A angio-TC de coronárias tem capacidade de afastar falso-positivos da SPECT.


Subject(s)
Humans , Male , Female , Middle Aged , Coronary Artery Disease/diagnostic imaging , Tomography, Emission-Computed, Single-Photon/methods , Coronary Angiography/methods , Myocardial Perfusion Imaging/methods , Coronary Artery Disease/physiopathology , Cineangiography/methods , Myocardial Reperfusion Injury/physiopathology , Myocardial Reperfusion Injury/diagnostic imaging , ROC Curve , Sensitivity and Specificity , Computed Tomography Angiography
7.
Radiol. bras ; 52(2): 92-96, Mar.-Apr. 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1002983

ABSTRACT

Abstract Objective: The purpose of this study was to evaluate the effects of electrical muscle stimulation (EMS) on muscles, using 99mTc-sestamibi SPECT/CT. Materials and Methods: We prospectively enrolled 20 consecutive male professional water polo players. The mean age was 25 years (range, 18-36 years). All athletes underwent 99mTc-sestamibi SPECT/CT of the thigh (rectus femoris and vastus medialis muscle groups) before and after EMS. Images were quantified to identify increases in perfusion after EMS. Results: Before EMS, there were no significant differences between the right and left thigh (rectus femoris and vastus medialis muscles) in terms of perfusion (p = 0.4). However, the comparison between the pre- and post-EMS analyses of the same muscle groups showed significant differences in radiotracer uptake (p < 0.001), with a mean increase in perfusion of 128% for the rectus femoris muscle group (95% CI: 0.86-1.61) and 118% for the vastus medialis muscle group (95% CI: 0.96-1.79). Conclusion: 99mTc-sestamibi SPECT/CT is an objective means of evaluating blood flow in muscles submitted to EMS, which appears to promote significant increases in such blood flow.


Resumo Objetivo: O objetivo deste estudo foi avaliar o efeito da estimulação elétrica transcutânea na musculatura esquelética utilizando-se SPECT/CT com 99mTc- sestamibi. Materiais e Métodos: Foram prospectivamente avaliados 20 atletas masculinos de polo aquático (18-36 anos de idade; média de 25 anos). Todos os atletas foram submetidos a SPECT/CT com 99mTc- sestamibi das coxas antes e após estimulação elétrica transcutânea dos grupos musculares reto femoral e vasto medial. As imagens foram quantificadas para identificar aumento da perfusão. Resultados: A comparação da perfusão dos grupos musculares (reto femoral e vasto medial) direito versus esquerdo durante o repouso não demonstrou diferença significativa (p = 0,4). Entretanto, quando comparados esses mesmos grupos musculares antes e após a estimulação elétrica, observou-se diferença significativa na captação do traçador (p < 0,001), com aumento perfusional médio de 128% do grupo reto femoral (IC 95%: 0,86-1,61) e 118% do grupo vasto medial (IC 95%: 0,96-1,79) no grupo estimulado. Conclusão: A SPECT/CT com 99mTc- sestamibi é capaz de demonstrar de forma objetiva que a estimulação elétrica transcutânea aumenta significativamente o fluxo sanguíneo muscular.

8.
Einstein (Säo Paulo) ; 14(3): 408-414, July-Sept. 2016. graf
Article in English | LILACS | ID: lil-796971

ABSTRACT

ABSTRACT Objective: To present the result of upgrading a clinical gamma-camera to be used to obtain in vivo tomographic images of small animal organs, and its application to register cardiac, renal and neurological images. Methods: An updated version of the miniSPECT upgrading device was built, which is composed of mechanical, electronic and software subsystems. The device was attached to a Discovery VH (General Electric Healthcare) gamma-camera, which was retired from the clinical service and installed at the Centro de Imagem Pré-Clínica of the Hospital Israelita Albert Einstein. The combined system was characterized, determining operational parameters, such as spatial resolution, magnification, maximum acceptable target size, number of projections, and acquisition and reconstruction times. Results: Images were obtained with 0.5mm spatial resolution, with acquisition and reconstruction times between 30 and 45 minutes, using iterative reconstruction with 10 to 20 iterations and 4 projection subsets. The system was validated acquiring in vivo tomographic images of the heart, kidneys and brain of normal animals (mice and adult rats), using the radiopharmaceuticals technetium-labeled hexakis-2-methoxy-isobutyl isonitrile (99mTc-Sestamibi), technetium-labeled dimercaptosuccinic acid (99mTc-DMSA) and technetium-labeled hexamethyl propyleneamine oxime (99mTc-HMPAO). Conclusion: This kind of application, which consists in the adaptation for an alternative objective of already existing instrumentation, resulted in a low-cost infrastructure option, allowing to carry out large scale in vivo studies with enhanced quality in several areas, such as neurology, nephrology, cardiology, among others.


RESUMO Objetivo: Apresentar o resultado da adaptação de uma gama câmara clínica para uso dedicado na obtenção de imagens tomográficas in vivo de órgãos de pequenos animais de experimentação, e de sua aplicação na obtenção de imagens cardíacas, renais e neurológicas. Métodos: Foi construída uma versão atualizada do dispositivo de adaptação miniSPECT, composto por três subsistemas: mecânico, eletrônico e de software. O dispositivo foi montado em uma câmara Discovery VH da General Electric Healthcare, retirada do serviço clínico e instalada no Centro de Imagem Pré-Clínica do Hospital Israelita Albert Einstein. O sistema combinado foi caracterizado, determinando parâmetros de funcionamento como resolução espacial, magnificação, limites de tamanho dos alvos de estudo, número de projeções, tempo de registro e tempo de reconstrução das imagens tomográficas. Resultados: Foram obtidas imagens com resolução espacial de até 0,5mm, com tempos de registro e reconstrução de 30 a 45 minutos, utilizando reconstrução iterativa com 10 a 20 iterações e 4 subconjuntos de projeções. O sistema foi validado obtendo imagens tomográficas in vivo do coração, dos rins e do cérebro de animais normais (camundongos e ratos adultos), utilizando os radiofármacos hexaquis-2-metoxi-isobutil-isonitrila marcado com 99mTc (Sestamibi-99mTc), ácido dimercaptosuccínico marcado com 99mTc (DMSA-99mTc) e hexametil-propileno-amina-oxima marcada com 99mTc (HMPAO-99mTc). Conclusão: Este tipo de aplicação, que consiste na adaptação para um objetivo alternativo de instrumentação já existente, constituiu-se em uma opção de infraestrutura de baixo custo, que permite realizar estudos in vivo em larga escala, com qualidade aprimorada, em áreas diversas, como neurologia, nefrologia, cardiologia, entre outras.


Subject(s)
Animals , Male , Tomography, Emission-Computed, Single-Photon/instrumentation , Molecular Imaging/instrumentation , Translational Research, Biomedical/instrumentation , Brain/diagnostic imaging , Tomography, Emission-Computed, Single-Photon/methods , Phantoms, Imaging , Models, Animal , Molecular Imaging/methods , Heart/anatomy & histology , Heart/diagnostic imaging , Kidney/diagnostic imaging , Mice
9.
Arq. bras. cardiol ; 105(4): 345-352, tab, graf
Article in English | LILACS | ID: lil-764470

ABSTRACT

AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.


ResumoFundamento:Já foi demonstrado que a imagem na posição prona minimiza a atenuação dos tecidos diafragmáticos e da mama.Objetivos:Determinar o papel da imagem na posição prona na redução de estudos de perfusão em repouso e angiografias coronárias realizadas de forma desnecessária, assim diminuindo o tempo de investigação e exposição à radiação.Métodos:Foram examinados 139 pacientes, 120 com um defeito de perfusão da parede inferior e 19 com defeito de perfusão da parede anterior que pudessem representar um artefato de atenuação. Imagens pós-estresse foram adquiridas nas posições supina e prona. A angiografia coronária foi usada como o “padrão ouro” para avaliar a patência da artéria coronária. O estudo foi encerrado e a imagem em repouso não foi necessária na presença de melhoria completa do defeito na posição prona. Uma interpretação quantitativa foi realizada. Os resultados foram comparados com os dados clínicos e achados angiográficos.Resultados:A aquisição de imagem na posição prona revelou corretamente a melhoria do defeito em 89 pacientes (89/120) com artefato de atenuação na parede inferior e 12 pacientes (19/12) na parede anterior. A análise quantitativa demonstrou diferença estatisticamente significante nas somas dos escores de estresse (SSS) médios nos estudos da posição supina e SSS médios dos estudos na posição prona em pacientes com desaparecimento do defeito da parede inferior na posição prona e artéria coronária patente (resultados negativos verdadeiros). A diferença média dos SSS nas posições supina e prona foi maior com os defeitos desaparecidos do que com os que permaneceram.Conclusão:A cintilografia de perfusão miocárdica com Tecnécio-99m (Tc-99m) tetrofosmin com o paciente na posição prona supera a atenuação de tecidos moles; Além disso, oferece uma abordagem precisa e de baixo custo para limitar o número de estudos de perfusão em repouso e realização de angiografias coronárias desnecessárias.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Artifacts , Myocardial Perfusion Imaging/methods , Prone Position , Patient Positioning/methods , Radiation Exposure/prevention & control , Tomography, Emission-Computed, Single-Photon/methods , Coronary Angiography/methods , Coronary Artery Disease , Exercise Test , Myocardial Infarction , Organophosphorus Compounds , Organotechnetium Compounds , Radiopharmaceuticals , Risk Assessment , Sensitivity and Specificity , Statistics, Nonparametric , Time Factors
10.
Rev. Assoc. Med. Bras. (1992) ; 60(4): 311-317, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-720985

ABSTRACT

Objective: despite the technologic advances in myocardial perfusion imaging, we keep using an uncomfortable and sometimes impracticable patient position - supine with arms raised above the head (U). The purpose of this study was to investigate whether perfusion and functional cardiac gated SPECT scan results of acquisition U are equivalent to another position modality: supine with arms down at the sides of the trunk (D). Methods and Results: we performed U acquisition and in sequence D acquisition in 120 patients (pts) using a one-day MPI (rest-gated/stress), with 99mTc-sestamibi (370 MBq and 1110 MBq). Images were processed by the iterative reconstruction method (OSEM). Rest (R) and stress (S) studies were scored using 17-segments model. Functional parameters (left ventricular ejection fraction, and volumes) were automatically obtained by the quantitative gated SPECT (QGS) program. According to the degree of stress defects observed in U study, the patients were categorized in two subgroups: normal (SSS ≤ 3 or < 5%) and abnormal (SSS>3 or ≥ 5%). Shoulder/back pain occurred in 23.3% of U patients and in 5% of D. No significant differences between U and D were found for SSS (p = 0.82) and SRS (p = 0.74) in normal group. In abnormal group, good correlation was found between U and D modes for SSS (Rho = 0.95, p = 0.0001) and SRS (Rho = 0.96 p = 0.0001), but the mean SSS (12.53 ± 7.54) and SRS (10.60 ± 7.08) values of D were significantly lower (p < 0.05) than SSS (13.43 ± 6.81) and SRS (11.33 ± 6.97) of U mode. Function measurements presented good correlations, except for end-diastolic volume (p = 0.0001). Conclusion: although D mode appears to be more comfortable and presented a good correlation with U values of SSS and SRS, in abnormal pts, the extent and severity of defects can be underestimated. Considering clinical implications of an accurate perfusion measurement, the acquisition with the ...


Objetivo: no estudo de perfusão miocárdica, apesar dos avanços tecnológicos, continuamos utilizando o desconfortável e às vezes impraticável posicionamento em decúbito dorsal com braços acima da cabeça (U). O objetivo do estudo foi investigar se os resultados da perfusão e da função cardíacas obtidos com a aquisição U são equivalentes ao de outra modalidade de posição: com braços para baixo nas laterais do tronco (D). Métodos e resultados: adquirida a aquisição U, na sequência foi realizada a aquisição D em 120 pacientes (pts) em um único dia (repouso e estresse sincronizado ao ECG), com 99mTc-sestamibi (370 MBq e 1110 MBq). As imagens foram processadas usando reconstrução iterativa (OSEM). Cada estudo foi quantificado usando o modelo de 17-segmentos ao repouso (R) e ao estresse (S). Os parâmetros funcionais (fração de ejeção do ventrículo esquerdo e volumes) foram obtidas automaticamente pelo programa gated SPECT quantitativa (QGS). De acordo com a dimensão da alteração perfusional no estresse na aquisição U, os pacientes foram classificados em dois subgrupos: 80 pts normais (SSS ≤ 3 ou < 5%) e 40 pts anormais (SSS > 3 ou ≥ 5%). Dor no ombro e/ou nas costas ocorreu em 23,3% dos pacientes de U e em 5% de D. Não houve diferenças significativas entre U e D quanto ao SSS (p = 0,82) e SRS (p = 0,74) no grupo normal. No grupo anormal, boa correlação foi encontrada entre U e D para SSS (Rho = 0,95, p = 0,0001) e SRS (Rho = 0,96 p = 0,0001), entretanto a média dos valores de SSS (12,53 ± 7,54) e SRS (10,60 ± 7,08 ) de D foram significativamente menores (p < 0,05) que o SSS (13,43 ± 6,81) e SRS (11,33 ± 6,97) de U. As medidas de função apresentaram boas correlações, ...


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Arm , Myocardial Perfusion Imaging/methods , Patient Positioning/methods , Supine Position , Tomography, Emission-Computed, Single-Photon/methods , Rest , Stroke Volume
11.
Arq. neuropsiquiatr ; 70(9): 667-673, Sept. 2012. ilus, tab
Article in English | LILACS | ID: lil-649299

ABSTRACT

The clinical diagnosis of Parkinson's disease (PD) is susceptible to misdiagnosis, especially in the earlier stages of the disease. Recently, in vivo imaging techniques assessing the presynaptic dopamine transporter (DAT) have emerged as a useful tool in PD diagnosis, improving its accuracy. OBJECTIVE: It was to illustrate the clinical usefulness of a brain single-photon emission computed tomography (SPECT) DAT ligand, and highlight relevant aspects of scans without evidence of dopaminergic deficit (SWEDDs) in this context. CASES: We described four representative patients with clinically unclear parkinsonian syndromes who underwent [99mTc]-TRODAT-1 SPECT and reviewed the clinical implications. CONCLUSION: DAT-SPECT is an important, cost-effective, technique for the differential diagnosis of parkinsonian syndromes. Additionally, SWEDD cases present clinical and paraclinical peculiarities that may retrospectively identify them as essential/dystonic tremor. The lack of histopathological data limits further conclusions.


O diagnóstico clínico da doença de Parkinson (DP) pode estar sujeito a erros especialmente nas fases iniciais da doença. Recentemente, técnicas de imagem in vivo que avaliam o transportador de dopamina pré-sináptico (DAT) surgiram como uma ferramenta empregada no diagnóstico da DP, melhorando sua acurácia. OBJETIVO: Foi demonstrar a utilização clínica de um traçador de tomografia computadorizada por emissão de fóton único (SPECT) e destacar importantes aspectos dos casos de SWEDDs (exames sem evidência de déficit dopaminérgico) neste contexto. CASOS: Descrevemos quatro pacientes representativos de síndromes parkinsonianas clinicamente incertas submetidos a [99mTc]-TRODAT-1 SPECT e revisamos suas implicações. CONCLUSÃO: O DAT-SPECT é uma técnica importante e eficiente para o diagnóstico diferencial das síndromes parkinsonianas. Além disso, os casos de SWEDDs apresentam peculiaridades clínicas e paraclínicas que podem retrospectivamente identificá-los como tremor essencial ou tremor distônico. As conclusões têm alcance limitado pela falta de dados histopatológicos.


Subject(s)
Adult , Female , Humans , Middle Aged , Dopamine Plasma Membrane Transport Proteins/metabolism , Organotechnetium Compounds , Parkinsonian Disorders , Radiopharmaceuticals , Tomography, Emission-Computed, Single-Photon , Tropanes , Diagnosis, Differential , Magnetic Resonance Imaging , Tomography, Emission-Computed, Single-Photon/economics
12.
Rev. méd. Minas Gerais ; 21(3)jul.-set. 2011. ilus, tab
Article in Portuguese | LILACS-Express | LILACS | ID: lil-621138

ABSTRACT

Imagem molecular é denominação relativamente recente para procedimentos diagnósticos por imagem que envolvem reações entre agentes de imagem e moléculas-alvo específicas, como enzimas e receptores celulares. Essencialmente, um agente de imagem se constitui de uma porção que interage com um alvo específico, enzima ou receptor celular e uma porção que permite a sua detecção, como, por exemplo, um elemento radioativo, uma partícula magnética ou uma molécula fluorescente. A imagem molecular permite abordar processos biológicos nos níveis celular e subcelular, em organismos vivos intactos. Embora a Medicina Nuclear seja o método, de longe, mais utilizado na área do diagnóstico por imagem que se enquadra na imagem molecular, novas abordagens envolvendo a fluorescência, a ressonância magnética e a ultrassonografia, entre outros, despontam com grande potencial para emprego clínico e pré-clínico. São apresentados exemplos de abordagens pelos diversos métodos de imagem.


Molecular Imaging is a relatively new denomination for diagnostics by imaging procedures that involve reactions between imaging agents and targeting molecules such as enzymes and cellular receptors. Essentially, an imaging agent has a targeting component that interacts with the enzyme or cellular receptors and a component that can be detected, for example, a radioactive element, a magnetic particle or a fluorescent molecule. Molecular Imaging is used to study biological processes at the cellular and sub-cellular levels within intact living organisms. Although Nuclear Medicine has been by far the method more utilized in diagnostic imaging that can be considered Molecular Imaging, new approaches with fluorescence, Magnetic Resonance Imaging and Ultrasound, among others, have a great potential for clinical and preclinical studies. Examples of studies with these methods are presented.

13.
São Paulo med. j ; 128(4): 239-243, July 2010. ilus, tab
Article in English | LILACS | ID: lil-566420

ABSTRACT

CONTEXT: Non-small cell lung carcinomas (NSCLCs) of the superior sulcus are considered to be the most challenging type of malignant thoracic disease. In this disease, neoplasms originating mostly from the extreme apex of the lung expand to the chest wall and thoracic inlet structures. Multiple imaging procedures have been applied to identify tumors and to stage and predict tumor resectability in surgical operations. Clinical examinations to localize pain complaints in shoulders and down the arms, and to screen for Horner's syndrome and abnormalities seen in paraclinical assessments, have been applied extensively for differential diagnosis of superior sulcus tumors. Although several types of imaging have been utilized for diagnosing and staging Pancoast tumors, there have been almost no reports on the efficiency of whole-body bone scans (WBBS) for detecting the level of abnormality in cases of superior sulcus tumors. CASE REPORT: We describe a case of Pancoast tumor in which technetium-99m methylene diphosphonate (Tc-99m MDP) bone single-photon emission-computed tomography (SPECT) was able to accurately detect multiple areas of abnormality in the vertebrae and ribs. In describing this case, we stress the clinical and diagnostic points, in the hope of stimulating a higher degree of suspicion and thereby facilitating appropriate diagnosis and treatment. From the results of this study, further clinical trials to evaluate the potential of SPECT as an efficient imaging tool for the work-up on cases of Pancoast tumor are recommended.


CONTEXTO: Carcinomas pulmonares de células não pequenas (NSCLCs) do sulco superior são considerados como o maior desafio nos tumores malignos torácicos. Nesta doença, as neoplasias se originam principalmente do ápice do pulmão e se expandem pela parede e pelas estruturas torácicas. Diversas técnicas de imagem têm sido utilizadas para identificar e estagiar os tumores, permitindo um prognóstico para a sua ressecção em procedimentos cirúrgicos. O exame clínico tem sido bastante usado para diagnóstico diferencial de tumores do sulco superior nas queixas de dores no ombro, síndrome de Horner e anormalidades observadas em exames paraclínicos. Embora diversos tipos de exames de imagem sejam utilizados para diagnóstico e estadiamento de tumores de Pancoast, praticamente não existem relatos sobre a eficácia do exame ósseo do corpo todo (WBBS) na detecção do nível de anormalidade em casos de tumores do sulco superior. RELATO DE CASO: Descrevemos um caso de tumor de Pancoast, em que foi realizada a tomografia computadorizada óssea por emissão de fóton único (SPECT) com metileno difosfonato de tecnécio-99 (Tc-99m MDP). Este exame foi capaz de detectar com acurácia as múltiplas áreas de anormalidade em vértebras e costelas. Ao descrever este caso, os autores ressaltam os pontos clínicos e diagnósticos, esperando estimular maior grau de suspeita, facilitando assim o diagnóstico e tratamento apropriados. A partir dos resultados deste trabalho, outros estudos clínicos podem avaliar o potencial do SPECT como uma ferramenta eficiente de imagem a ser recomendada na investigação de casos de tumor de Pancoast.


Subject(s)
Aged , Humans , Male , Pancoast Syndrome , Tomography, Emission-Computed, Single-Photon/methods , Carcinoma, Non-Small-Cell Lung/diagnosis , Lung Neoplasms/diagnosis , Radiopharmaceuticals , Spine
14.
Arq. neuropsiquiatr ; 68(2): 161-167, Apr. 2010. ilus, tab
Article in English | LILACS | ID: lil-545909

ABSTRACT

Brain SPECT imaging (BSI) with statistical parametric mapping (SPM) offers a clear and accurate vision of perfusion changes. OBJECTIVE: To study brain perfusion abnormalities in adolescents' dependent of multiple drugs. METHOD: Sixteen male patients (15.1±2.1 years) were submitted to 99mTc-HMPAO BSI with SPM. RESULTS: Cortical hypoperfusion occurred in 7/16 patients (44 percent). There was a significant inverse correlation between the number of hypoperfused regions and the patient's age (p= -0.6737; p=0.004) and with the age when the drug dependence began (p= -0.5616; p=0.023). There was also a tendency towards an inverse correlation between regions of hypoperfusion and the duration of the drug dependence. CONCLUSION: BSI with SPM can help detect hypoperfusion in adolescents dependent on multiple drugs. The younger the patients, the more regions of hypoperfusion are noted. Probably, the neuronal plasticity has an important role in this phenomenon because the highest neural activity occurs in childhood.


SPECT cerebral (SC) com statistical parametric mapping (SPM) oferece uma visão clara e acurada de alterações perfusionais. OBJETIVO: Avaliar anormalidades perfusionais cerebrais em adolescentes usuários de múltiplas drogas. MÉTODO: Dezesseis pacientes masculinos (15,1±2,1 anos) foram submetidos a SC com SPM utilizando-se HMPAO-99mTc. RESULTADOS: Hipoperfusão cortical ocorreu em 7/16 pacientes (44 por cento). Houve uma significativa correlação inversa entre o número de áreas hipoperfundidas e a idade dos pacientes (p= -0,6737; p=0,004) e com a idade quando iniciaram o abuso das drogas (p= -0,5616; p=0,023). Também houve uma tendência para uma correlação inversa entre as áreas de hipoperfusão e a duração do abuso de drogas. CONCLUSÃO: SC com SPM pode auxiliar na detecção de hipoperfusão cortical em adolescentes dependentes de múltiplas drogas. Quanto menor a idade, mais áreas de hipoperfusão são identificadas. Provavelmente a plasticidade neuronal tem importante papel neste fenômeno, pois a maior atividade neuronal ocorre na infância.


Subject(s)
Adolescent , Child , Humans , Male , Brain Mapping , Brain/blood supply , Brain , Substance-Related Disorders , Tomography, Emission-Computed, Single-Photon , Age Factors , Radiopharmaceuticals , Time Factors
15.
Rev. Soc. Bras. Fonoaudiol ; 14(3): 315-322, 2009. tab
Article in Portuguese | LILACS | ID: lil-529313

ABSTRACT

OBJETIVO: Relacionar as habilidades auditivas, metafonológicas e de neuroimagem em escolares com dislexia do desenvolvimento e comparar os achados dessas habilidades em escolares com bom desempenho acadêmico. MÉTODOS: Participaram deste estudo 20 escolares, sendo dez com diagnóstico interdisciplinar de dislexia do desenvolvimento e dez com bom desempenho acadêmico, submetidos a avaliações audiológica, do processamento auditivo e de consciência fonológica. Os escolares com dislexia do desenvolvimento foram submetidos a exame de imagem (SPECT). RESULTADOS: Os resultados indicaram diferença estatisticamente significante entre as habilidades auditivas de sequência para sons verbais, mensagem competitiva ipsi e contralateral, dicótico de dígitos e dissílabos alternados e habilidades de síntese, segmentação, manipulação e transposição fonêmica. Entre os escolares com dislexia do desenvolvimento, evidenciou-se hipoperfusão da porção mesial do lobo temporal. CONCLUSÃO: Os achados deste estudo evidenciaram correlação entre provas de memória auditiva e manipulação silábica e fonêmica e associação entre habilidades auditivas e fonológicas, sugerindo que os processos auditivos interferem diretamente na percepção de aspectos acústicos, temporais e sequenciais dos sons para formação de uma representação fonológica estável, e que isto pode ser decorrente da presença de alterações de fluxo sanguíneo no lobo temporal.


PURPOSE: To correlate auditory and metaphonological abilities and neuroimaging in students with developmental dyslexia, and to compare these findings to those obtained with students with good academic performance. METHODS: Twenty children participated in this study: ten with an interdisciplinary diagnostic of developmental dyslexia, and ten students with good academic performance. All subjects carried out audiologic, auditory processing and phonological awareness evaluations. The students with developmental dyslexia were submitted to imaging exam (SPECT). RESULTS: The results indicated a statistically significant difference between the hearing abilities of verbal sound sequences, contra and ipsilateral competing message, dichotic digits and alternate disyllables, and the metaphonological abilities of phonemic synthesis, segmentation, manipulation and transposition. Mesial temporal lobe hypoperfusion was evidenced among subjects with developmental dyslexia. CONCLUSION: The findings of the present study evidenced correlation between auditory memory tasks and syllabic and phonemic manipulation, and association between auditory and phonological abilities, suggesting that auditory processes interfere directly in the perception of acoustic, temporal and sequential aspects of sounds to form a stable phonological representation, and that this might be caused by the presence of blood flow changes on the temporal lobe.


Subject(s)
Humans , Child , Auditory Perception , Dyslexia/diagnosis , Learning , Tomography, Emission-Computed, Single-Photon
16.
Arq. bras. cardiol ; 90(5): 333-338, maio 2008. ilus, graf, tab
Article in English, Portuguese | LILACS | ID: lil-482924

ABSTRACT

FUNDAMENTO: Alguns pacientes apresentam fração de ejeção do ventrículo esquerdo (FEVE) superestimada na cintilografia miocárdica com sincronização eletrocardiográfica (gated SPECT). OBJETIVO: Estabelecer a relação entre fatores biológicos e FEVE superestimada. MÉTODOS: Selecionamos 3.838 pacientes que realizaram gated SPECT entre 20/5/2000 e 16/9/2005, com imagens normais de perfusão e FEVE >50 por cento. Analisamos as variáveis: sexo (29,4 por cento feminino e 70,6 por cento masculino), idade (de 20 a 94 anos - média: 56 anos), peso (de 33,5 a 150 kg - média: 79,6 kg), altura (de 138 a 220 cm - média: 171 cm) e IMC (de 13,9 a 54 - média: 27,2). Em um subgrupo de 1.002 pacientes que realizaram ecocardiograma, incluímos as variáveis diâmetros diastólico (de 36 a 68 mm - média 47,5 mm) e sistólico (de 22 a 41 mm - média 29,8 mm). Dividimos os pacientes em dois grupos: FEVE normal (<80 por cento) e superestimada (>80 por cento). A Razão de Chances (RC) para apresentar FEVE superestimada foi calculada para cada variável por regressão logística. RESULTADOS: Encontramos as seguintes Razões de Chances (p < 0,005): sexo feminino RC = 3,585 (IC95 por cento: 2,745 a 4,683), idade em anos RC = 1,020 (IC95 por cento: 1,011 a 1,029) e altura em cm RC = 0,893 (IC95 por cento: 0,829 a 0,962). O peso e o IMC não se associaram a FEVE significativamente (p>0,2). No subgrupo de 1.002 pacientes, encontramos influência estatisticamente significativa na obtenção da FEVE superestimada para as variáveis diâmetro sistólico, sexo e altura. CONCLUSÃO: Apesar de o diâmetro sistólico influenciar na obtenção da FEVE superestimada, as variáveis sexo e altura apresentam influência independente na superestimação da FEVE pelo gated SPECT.


BACKGROUND: Some patients present an overestimated left ventricular ejection fraction (LVEF) on electrocardiogram-gated myocardial scintigraphy (gated SPECT). OBJECTIVE: To establish the relationship between biological factors and overestimated LVEF. METHODS: We selected 3838 patients who underwent gated SPECT between May 20, 2000 and September 16, 2005 with normal perfusion images and LVEF >50 percent. The following variables were analyzed: gender (29.4 percent females and 70.6 percent males), age (from 20 to 94 years - mean: 56 years), weight (from 33.5 to 150 kg - mean: 79.6 kg), height (from 138 to 220 cm - mean: 171 cm) and BMI (from 13.9 to 54 - mean: 27.2). In a subgroup of 1002 patients who underwent echocardiogram, the diastolic diameter (from 36 to 68 mm - mean 47.5 mm) and systolic diameter (from 22 to 41 mm - mean 29.8 mm) variables were included. The patients were divided into two groups: normal LVEF (<80 percent) and overestimated LVEF (>80 percent). The odds ratio (OR) for presenting an overestimated LVEF was calculated for each variable using logistic regression. RESULTS: The following odds ratios were found (p < 0.005): female gender OR = 3.585 (95 percentCI: 2.745 to 4.683), age in years OR = 1.020 (95 percentCI: 1.011 to 1.029) and height in cm OR = 0.893 (95 percentCI: 0.829 to 0.962). Weight and BMI were not significantly associated with LVEF (p>0.2). In the subgroup of 1002 patients, a statistically significant influence was found in overestimated LVEF values for the systolic diameter, gender and height variables. CONCLUSION: Although systolic diameter influences the overestimation of LVEF, the gender and height variables have an independent influence on LVEF overestimation by gated SPECT.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography , Stroke Volume/physiology , Ventricular Dysfunction, Left , Biological Factors , Body Height , Diastole/physiology , Heart Ventricles , Retrospective Studies , Sex Factors , Systole , Young Adult
SELECTION OF CITATIONS